What was found
PAX ENTRY FWD FLOOR SUPPORT HINGE RELEIF ANGLE CORRODED. R & R PAX ENTRY CLOSING FITTING IAW SRM 51-42-21, W/C 2108.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PAX ENTRY FWD FLOOR SUPPORT HINGE RELEIF ANGLE CORRODED. R & R PAX ENTRY CLOSING FITTING IAW SRM 51-42-21, W/C 2108.