As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
HFEC OPEN HOLE INSP FOUND CRACK ON STA 1265 RT FLOOR INTERCOSTAL WEB AS MARKED. COMPLIED WITH EN 1115-10 (REPAIR FOR CRACK ON STA 1265 FRAME WEB 65B15095-12 SB 747-53A2416 INSP TIME LIMITED REPAIR FOR 24 MONTHS OR 2,000 FLIGHT CYCLES FROM THE TIME OF REPAIR, WHICHEVER COMES FIRST ON EXISTING PRESSURE DECK SEAL FITTING PER DWG 65B07992 REQUIREMENTS.