What was found
HFEC INSP FOUND SPLICE PLATE CRACK APPROX 1 INCH ON BS 400 S45R O/B LWR CHORD OF BULKHEAD AREA. CRACKED END STOP DRILLED AS PER SRM 53-30-03 FIGURE 35 REVISION 117. HFEC INSPECTION CARRIED OUT AROUND STOP DRILL HOLE AND FOUND CRACKED CONTAINED. FABRICATED REPAIR DOUBLERS USING MATERIAL AMS 5518-0.050 INCH AND HOLES PICKED UP AS PER SRM 53-30-03 FIGURE 35 REVISION 117. CADMIUM PLATING CARRIED OUT ON THE FABRICATED REPAIR DOUBLERS AS PER BOEING SOPM 20-42-01 REVISION 23 IN ACCORDANCE WITH SRM 53-30-03 FIGURE 35 REVISION 117. FABRICATED REPAIR DOUBLERS PROTECTED AND INSTALLED AS PER SRM 51-10-02 AND SRM 53-30-03 FIGURE 35 REVISION 117.