What was found
DURING SCHEDULED INSPECTION AT AERO CORP IN LAKE CITY, FL, FOUND THE AFT CARGO PIT S-30 IS CORRODED FROM STATION 897 TO STATION 965. REMOVED CORROSION FOUND TO BE OUT OF LIMITS IAW DC-9 SRM 51-01 FIG 1. REMOVED CORRODED AREA OF STRINGER 30 IAW DC-9 SRM 51-01, TREATED AND PRIMED LONGERON IAW DC-9 SRM 51-10-3, 51-60-0. (M)