What was found
DURING A SCHEDULED INSPECTION AT AERO CORP IN LAKE CITY, FL, THE FOLLOWING WAS FOUND, FRAME STATION 370 BETWEEN L29R AND L28R HAS DOUBLE DRILLED HOLES. FABRICATED ANGLE REPAIR USING 2024-0 .071, HEAT TREATED ANGLE, REPAIR FILLER FABRICATED FROM 2024-0 .125 INCH HEAT TREATED FILLER, DRILLED REPAIR ANGLE, PLUGGED HOLES IN FRAME. ALODINED AND PRIMED NEW REPAIRS, INSTALLED REPAIRS IAW EA 12-5310-29-C1067. (M)