What was found
DURING A SCHEDULED INSPECTION AT AERO CORP IN LAKE CITY, FL, THE FOLLOWING WAS FOUND, THE LEFT MAIN TANK XW 58.768 BETWEEN STRINGER 16-17 T-CAP IS CORRODED. XW 58-768 LEFT MAIN TANK BETWEEN STRINGER 16-17 T-CAP CORROSION COMPLIED WITH IAW AERO EO 97-475 REV IR DATED 2-14-97. (M)