What was found
DURING A SCHEDULED INSPECTION AT AERO CORP IN LAKE CITY, FL, THE FOLLOWING WAS FOUND, THE LEFT MAIN TANK XRS 85-69 STRINGER 17 LOWER CAP IS CORRODED ON LOWER STRINGER. LEFT MAIN TANK XRS 58-69 STRINGER 17 LOWER CAP CORROSION COMPLIED WITH IAW EO 97-475 REV IR DATED 02-14-97. (M)