What was found
DURING A SCHEDULED INSPECTION AT AERO CORP IN LAKE CITY, FL, THE FOLLOWING WAS FOUND, SUB FLOOR CORRODED AT STATION 196 LBL 21. REMOVED CORROSION, DETERMINED OUT OF LIMITS IAW DC-9 SRM 53-01 FIG 1 (DEPTH GAUGE A-0299) MORE THAN 20 PERCENT MATERIAL LOSS. FABRICATED WEB AND DOUBLER MATERIAL 7075-T6 .032 -1/-2/-3 DIMENSIONS 11 INCHES BY 60 INCHES, 14.5 BY 65.25 AND 2.25 BY 032 IAW DC-9 SRM 53-11-1 FIG 11. TREATED AND PRIMED IAW DC9 SRM 51-10-3. (M)