What was found
DURING A SCHEDULED INSPECTION AT AERO CORP IN LAKE CITY, FL, THE FOLLOWING WAS FOUND, THAT DURING INSPECTION FOR COMPLIANCE OF AD 89-08-10 IAW ASB 52-154 AND ASB 53-223. DETERMINED REPAIR INSTALLED IS A SINGLE SPLICE ATTACH ANGLE. REMOVED LT AND RT VERTICAL FIN ATTACH ANGLES. DURING ACCOMPLISHEMENT OF SB 53-223 SEVERAL ELONGATED HOLES WERE NOTED IN FUSELAGE SKIN. HOLES REPAIRED USING FREEZE P LUGS AND DOUBLERS IAW EO 97-433. NEW LT AND RT VERT FIN NR 027N1-1250/61865 ATTACHMENT ANGLES INST IAW SB 53-223. (M)