What was found
ATTACH FITTING RT WING, NR 1 SLAT MAIN TRACK (CENTER), GOUGED. BLENDED AREA IAW DC9 SRM 53-01, FIG 1. BLEND DEPTHS WITHIN LIMITS PER RES 1 1668, TREATED AREA IAW SRM 51-10-3 AND AERO EO 98-822, COMPLETED FORM 8110-3. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ATTACH FITTING RT WING, NR 1 SLAT MAIN TRACK (CENTER), GOUGED. BLENDED AREA IAW DC9 SRM 53-01, FIG 1. BLEND DEPTHS WITHIN LIMITS PER RES 1 1668, TREATED AREA IAW SRM 51-10-3 AND AERO EO 98-822, COMPLETED FORM 8110-3. (M)