What was found
TOP SIDE, BOTTOM EDGE AND BOTTOM SUPPORT RIBS AFT GALLEY CENTER FLOOR PANEL CORRODED BEYOND LIMITS. FABRICATED AND INSTALLED NEW SKIN IAW DC9 SRM 51-10-2. SEALED AND ASSEMBLED PANEL IAW DC9 SRM 51-30-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TOP SIDE, BOTTOM EDGE AND BOTTOM SUPPORT RIBS AFT GALLEY CENTER FLOOR PANEL CORRODED BEYOND LIMITS. FABRICATED AND INSTALLED NEW SKIN IAW DC9 SRM 51-10-2. SEALED AND ASSEMBLED PANEL IAW DC9 SRM 51-30-2.