What was found
FLOORBOARD ATTACH ANGLES FS 160 TO 220, BL 55L - BL55R, Z=0, CORRODED BEYOND LIMITS. FABRICATED NEW ANGLES, TREATED, PRIMED AND INSTALLED NEW ANGLES IAW DC9 SRM 51-10-3, 51-30-1, 51-30-2 AND 53-01 FIG 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOORBOARD ATTACH ANGLES FS 160 TO 220, BL 55L - BL55R, Z=0, CORRODED BEYOND LIMITS. FABRICATED NEW ANGLES, TREATED, PRIMED AND INSTALLED NEW ANGLES IAW DC9 SRM 51-10-3, 51-30-1, 51-30-2 AND 53-01 FIG 1.