What was found
AFT CARGO DOOR JAMB BETWEEN FS Y900-934, L28R, CORRODED. LOCATED, DRILLED, TREATED AND INSTALLED NEW SECTION DOOR PAN IAW DC9 SRM 51-30-1, 51-30-2, 53-04, FIG 44, AND 51-10-4.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT CARGO DOOR JAMB BETWEEN FS Y900-934, L28R, CORRODED. LOCATED, DRILLED, TREATED AND INSTALLED NEW SECTION DOOR PAN IAW DC9 SRM 51-30-1, 51-30-2, 53-04, FIG 44, AND 51-10-4.