What was found
CABIN STA Y-167-198, -X=44, FLOOR SUPPORT UPPER SURFACE HAS CORROSION. REMOVED CORROSION FROM STA 167-198 FLOOR SUPPORT GROUND BEYOND LIMITS. REMOVED FLOOR SUPPORT, FABBED NEW FLOOR SUPPORT P/N 2652479 2 BY 38, DRILLED TRIM TO FIT. TREATED AND PRIMED IAW DC-9 SRM 51-10-3, 53-01 FIG SRM 51-30-4, (DIAL CALIPER 3268-1) SRM 53-11-1 FIG 13.