What was found
DURING THE ACCOMPLISHMENT OF AD 88-24-08 INSP PER EO 12-5330-29-B1058 I/R, HFEC INDICATES EXTERNAL FUSELAGE SKIN CRACKED AT FS 617 RT LONG 1 SHEAR TIE. REMOVED 1 FASTENER IAW DC-9 SRM 51-30-2 HFEC VERIFIED CRACK IN SKIN AT COUNTERSINK IAW DC-9 STD PRACTICE PTC. REMOVED FASTENER CUT OUT 2.5 HOLE AT CRACK AREA IAW DC-9 SRM 53-04 FIG 38. FABBED REPAIR FINGER DOUBLER EXTERIOR DOUBLER AND SKIN FILLER IAW DC-9 SRM 51-10-3 6.98 BY 761 FINGER DOUBLER SKIN FILLER 2.65, EXTERIOR DOUBLER 8.58 BY 6.14.