What was found
STATION 996 LOWER WEBS HAVE EXTENSIVE CORROSION THROUGH OUT. LOWER CAP HAS CORROSION. FABRICATED LOWER WEBS FROM 7075 T6 .040 BY 9.5 BY 61 BY 12 BY 22 2 EACH. INSTALLED IAW DC-9 SRM 51-10-4, 51-30-5, AND 51-10-3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STATION 996 LOWER WEBS HAVE EXTENSIVE CORROSION THROUGH OUT. LOWER CAP HAS CORROSION. FABRICATED LOWER WEBS FROM 7075 T6 .040 BY 9.5 BY 61 BY 12 BY 22 2 EACH. INSTALLED IAW DC-9 SRM 51-10-4, 51-30-5, AND 51-10-3.