What was found
DURING C CHECK, FOUND INTERCOASTAL CORRODED BETWEEN STA 332 AND 351 LEVEL 2. REMOVED INTERCOASTAL FOUND TO BE OUT OF LIMITS. FABBED AND FORMED NEW INTERCOASTAL 19.5 X 1 X .5 X 27/8 FROM 7075 .050. HEAT TREATED TO 7075-T6 .050. TRIMMED TO FIT, DRILLED, DEBURRED, TREATED, AND PRIMED, IAW DC-9SRM 53-11-2, 51-10-2, 51-30-2, 51-30-3, AND 51-10-3.