What was found
RT FLOOR SUPPORT CORRODED BEYOND LIMIT AT STA 996 TO 965. REMOVED CORROSION AND FOUND SKIN CORRODED OUT OF LIMIT IN Z-ANGLE. FABRICATED SKIN FROM 7075T6, .032, AND Z-ANGLE FROM 7075T6, .032. DRILLED AND DEBURRED SKIN AND Z-ANGLE IAW DC9 SRM 51-10-2, 51-10-4. TREATED, PRIMED AND INSTALLED SKIN AND Z-ANGLE IAW DC9 SRM 51-30-5.