What was found
HORIZONTAL INTERCOASTAL CORRODED BEYOND LIMIT AT FS 600-610, L16, AN FS 710, L16. REMOVED CORROSION IAW DC9 SRM 51-30-3. LOSS LIMITS IAW DC9 SRM 53-01, FIG 1. CUT, TRIMMED AND FABRICATED INTERCOASTAL FROM 7075-0, 040, IAW DC9 SRM 53-11-3, FIG 1. HEAT TREATED IAW DC9 SRM 51-10-2A. LOCATED, DRILLED AND DEBURRED INTERCOASTAL IAW DC9 SRM 51-10-4. ALODINED AND PRIMED IAW DC9 SRM 51-10-3. INSTALLED IAW DC9 SRM 51-30-2 AND 51-30-5.