What was found
FORWARD PIT FRAME CORRODED TOP AND BOTTOM AT FS 541, L27L-28L. REMOVED CORROSON IAW DC9 SRM 51-10-3, SRM 53-01, FIG 1. REMOVED FLOOR SUPPORT FROM LONGERON 24R-24L IAW DC9 SRM 51-30-2. FABRICATED FLOOR SUPPORT FROM 7075-0, .063, TREATED, LOCATED, DRILLED, PRIMED AND INSTALLED IAW DC9 SRM 51-10-2, 51-10-2A, 51-10-4, 51-10-3 AND 51-30-2.