What was found
FORWARD PIT FRAME CORRODED BEYOND LIMIT AT FS 465, L30. REMOVED FASTENERS AND CORROSION IAW DC9 SRM 51-30-1. FABRICATED REPAIR, CLIP FILLER AND DOUBLERS IAW DC9 SRM 53-08, FIG 2A, 51-10-3, 51-30-2 AND 51-30-5. HEAT TREATED, ALODINED, PRIMED AND INSTALLED FABRICATED PARTS AND FASTENERS IAW DC9 SRM 51-10-2A, 51-10-3 AND 51-30-5.