What was found
FOUND CORROSION ON BTM (2 EA) CORNERS OF NR 4 AFT AFT GALLEY. CLEANED CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM 53-01 PAG 8. REMOVED AND FABRICATED ANGLE FOR BOTTOM OF NR 4 AFT GALLEY FROM S124943T 75 X 1.0 X 11.0 X ANGLE IAW SRM 53-01 FIG 2, 51-10-4, INSTALLED IAW SRM 51-30-2.