What was found
AFT STAIR RT FRAME HAS 2 INCH GOUGE MIDWAY DOWN AND CHAFFING AGAINST FUSELAGE. OUT OF LIMIT IAW DC9 SRM 52-01, CALIPER MEASURE A NR 1729. FABRICATED REPAIR ANGLES IAW DC9 52-01, FIG 2 AND INSTALLED WITH SEALANT.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT STAIR RT FRAME HAS 2 INCH GOUGE MIDWAY DOWN AND CHAFFING AGAINST FUSELAGE. OUT OF LIMIT IAW DC9 SRM 52-01, CALIPER MEASURE A NR 1729. FABRICATED REPAIR ANGLES IAW DC9 52-01, FIG 2 AND INSTALLED WITH SEALANT.