What was found
EXFOLIATED CORROSION ON BS 328 FLOORBEAM CAP UNDER TAPERED SHIN RBL 54. REMOVED CORROSION IAW SRM 51-10-6. MATERIAL LOSS TO BE OUT OF LIMITS. REMOVED T CHORD STA 328 LBL 15 RBL 65 IAW SRM 51-30-2 AND 53-10-9. FABRICATED REPAIR SECTION AND REPAIR ANGLES IAW SRM 53-10-4 FIG 5. ALODINED AND PRIMED REPAIR PARTS 1A-344431-1 AND 1A-34433-1,2. INSTALLED REPAIR PARTS IAW SRM 51-10-2, MM 51-21-21, AND 51-30-2.