What was found
AFT TOILET FLOOR SUPPORT AT BL 12 L BS 1016 IS CORRODED. REMOVED FLOOR SUPPORT IAW SRM 51-30-1. REMOVED CORROSION IAW SRM 51-10-6. FOUND TO BE OUT OF LIMITS. FABRICATED ANGLE REPAIR FROM 7075-0 .100 IAW SRM 51-40-3. DRILLED, TRIMMED, AND DEBURRED ANGLE REPAIR IAW SRM 51-30-1. PRIMED AND TREATED IAW SRM 51-10-2 AND MM 51-20-11. INSTALLED REPAIR ANGLE AT FLOOR SUPPORT IAW SRM 51-30-1. RE-INSTALLED FLOOR SUPPORT IAW SRM 51-30-1.