As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFT TOILET UNDER FLOOR SUPPORT AT BL0 BS 1016 IS CORRODED. REMOVED CORROSION IAW SRM 51-10-2. FLOOR SUPPORT FOUND TO BE OUT OF LIMITS IAW SRM 53-10-1 AND 51-10-1. REPAIRED EXTRUDED SECTION IAW SRM 51-40-4 FROM 7075 T6 511. INSTALLED FLOOR SUPPORT REPAIR IAW SRM 51-40-4.