What was found
TWO EACH DENTS LOCATED AT FS 250L, L18-17, OUT OF LIMIT. COLD WORKED DENTS AT STA 250-245L, BETWEEN L17-18L, IAW DC9 SRM 53-04, FIG 38. FABRICATED DOUBLER REPAIR IAW DC9 SRM 53-04, FIG 38. DRILLED, TRIMMED AND DEBURRED DOUBLER, TREATED AND PRIMED DOUBLER AND INSTALLED INTERNAL SKIN DOUBLER REPAIR IAW DC9 SRM 51-10-4, 51-10-3, AND 51-30-2.