What was found
FWD PIT FS 484-503, L30, CORRODED BEYOND LIMIT IAW DC9 SRM 53-01, FIG 1. REMOVED LONGERON IAW DC9 SRM 53-11-2, FIG 14, CUT, TRIMMED, DRILLED, INSTALLED NEW SECTION LONGERON AND SPLICES IAW DC9 SRM 51-30-3, 51-30-3. SPLICES MADE FROM 7075T7351..