What was found
FWD PIT FRAME FS 522, L24L-30, CORRODED. FABRICATED REPAIR FLOOR SUPPORT 7075-0, .063, HEAT TREATED, DRILLED, DEBURRED, TREATED, PRIMED AND INSTALLED FLOOR SUPPORT IAW DC9 SRM 51-10-3, 51-10-4, 51-10-2A, 53-21-0, 51-3-2 AND RES 981418.