What was found
CHAFED AREA IN ACCESS PANEL AFT UNDERSIDE AREA NR 1 ENGINE PYLON. BLENDED CHAFED AREA OUT OF LIMITS IAW SRM 54-10-1. FABRICATED DOUBLER, DRILLED, DEBURRED, ALODINED, AND PRIMED IAW SRM 51-10-2. INSTALLED DOULER IAW SRM 51-30-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.