What was found
FLOOR SUPPORT AT FS 328 TO 344 LB 12 IS CORRODED OUT OF LIMITS. REMOVED FLOOR SUPPORT AND FABRICATED REPAIR FROM BAC 1505-100604-15.5 IAW SRM 51-30-2 AND SRM 51-40-4. TREATED, PRIMED, AND INSTALLED IAW SRM 51-10-2, 51-20-11, 51-30-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR SUPPORT AT FS 328 TO 344 LB 12 IS CORRODED OUT OF LIMITS. REMOVED FLOOR SUPPORT AND FABRICATED REPAIR FROM BAC 1505-100604-15.5 IAW SRM 51-30-2 AND SRM 51-40-4. TREATED, PRIMED, AND INSTALLED IAW SRM 51-10-2, 51-20-11, 51-30-2.