What was found
AT FUS STA 219L STR 27L CORRODED BEYOND LIMITS THE SRM LIMIT UNDER STR TIE CLIP. CUT OUT SECTION OF CORRODED STRINGER. FABRICATED REPAIR STRINGER, DRILLED UP, DEBURRED, TREATED, PRIMED, AND INSTALLED IAW SRM 53-10-3 FIG 1, 51-10-2 AND 51-20-11.