What was found
FLOORBEAM AT FS 160 TO 200, RBL 45, CORRODED BEYOND LIMIT ON TOP AND AROUND SCREW HOLES. REMOVED CORRODED SECTION, FABRICATED AND INSTALLED NEW SECTION AT FLOOR SUPPORT IAW DC9 SRM 51-10-1, 51-10-3, 51-10-4 AND 51-30-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOORBEAM AT FS 160 TO 200, RBL 45, CORRODED BEYOND LIMIT ON TOP AND AROUND SCREW HOLES. REMOVED CORRODED SECTION, FABRICATED AND INSTALLED NEW SECTION AT FLOOR SUPPORT IAW DC9 SRM 51-10-1, 51-10-3, 51-10-4 AND 51-30-2.