What was found
DENT .O45 INCHES IN DEPTH AT FS 206.25, L21 AND 22R, OUT OF LIMIT IAW DC9 SRM 53-04, FIG 38. COLD WORKED AREA, FABRICATED, INSTALLED REPAIR IAW DC9 SRM 53-04, FIG 38 VIEW P, 51-10-3 AND MM 21-00.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DENT .O45 INCHES IN DEPTH AT FS 206.25, L21 AND 22R, OUT OF LIMIT IAW DC9 SRM 53-04, FIG 38. COLD WORKED AREA, FABRICATED, INSTALLED REPAIR IAW DC9 SRM 53-04, FIG 38 VIEW P, 51-10-3 AND MM 21-00.