What was found
FLOOR SUPPORT STRUCTURE LEFT OF CENTER LINE CORRODED BEYOND LIMIT IAW DC9 SRM 53-01 FIG 1 AT FS 965, LBL 30. CUT OUT CORRODED SECTION OF FLOORBEAM, FABRICATED AND INSTALLED NEW SECTION IAW DC9 SRM 53-05 FIG 20A.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR SUPPORT STRUCTURE LEFT OF CENTER LINE CORRODED BEYOND LIMIT IAW DC9 SRM 53-01 FIG 1 AT FS 965, LBL 30. CUT OUT CORRODED SECTION OF FLOORBEAM, FABRICATED AND INSTALLED NEW SECTION IAW DC9 SRM 53-05 FIG 20A.