What was found
CREASE AT FS 522, L28R, APPROXIMATELY 3 BY 5 TIMES .070 INCHES OUT OF LIMIT IAW DC9 SRM 53-04, FIG 38. CUT OUT AREA, REMOVED DOUBLER, FABRICATED AND INSTALLED REPAIR AND FINGER DOUBLER IAW DC9 SRM 51-10-2, 53-04, FIG 12, 51-30-2, 51-30-5. 51-10-4 AND AIRTRAN RES 981760.