What was found
AFT ENTRANCE DOOR LT SIDE WALL SUPPORT ANGLE CRACKED AND CORRODED. FABRICATED AND INSTALLED NEW ANGLE IAW DC9 SRM 51-30-2, 51-30-4, 52-11-0, FIG 2, 51-20-2A AND AIRTRAN RES 981705.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT ENTRANCE DOOR LT SIDE WALL SUPPORT ANGLE CRACKED AND CORRODED. FABRICATED AND INSTALLED NEW ANGLE IAW DC9 SRM 51-30-2, 51-30-4, 52-11-0, FIG 2, 51-20-2A AND AIRTRAN RES 981705.