What was found
Z ANGLE FLOOR SUPPORT STRUCTURE AT FS 965, LBL1 - LBL22, CORRODED AND CRACKED ON O/B END. REMOVED Z ANGLE, FABRICATED AND INSTALLED NEW ANGLE IAW DC9 SRM 51-30-2, 51-10-4 AND 51-10-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
Z ANGLE FLOOR SUPPORT STRUCTURE AT FS 965, LBL1 - LBL22, CORRODED AND CRACKED ON O/B END. REMOVED Z ANGLE, FABRICATED AND INSTALLED NEW ANGLE IAW DC9 SRM 51-30-2, 51-10-4 AND 51-10-2.