What was found
DENTS AT FS 927R AND 929R, L24, .053X2 DX=38, .029X2 DX=69, 0UT LIMIT IAW DC9 SRM 53-04, FIG 38. COLD WORKED DENTS, VERIFIED NO CRACKS BY HFEC, FABRICATED AND INSTALLED DOUBLER IAW DC9 SRM 53-04, FIG 38 AND 51-30-1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DENTS AT FS 927R AND 929R, L24, .053X2 DX=38, .029X2 DX=69, 0UT LIMIT IAW DC9 SRM 53-04, FIG 38. COLD WORKED DENTS, VERIFIED NO CRACKS BY HFEC, FABRICATED AND INSTALLED DOUBLER IAW DC9 SRM 53-04, FIG 38 AND 51-30-1.