What was found
DENT AT FS 213.5L, L16-17, .023 X 1/2 DX=22, OUT OF LIMIT PER SRM 53-04, FIG 38, SHEET 10. COLD WORKED DENTS, VERIFIED NO CRACKS BY HFEC, FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC9 SRM 51-04, FIG 38 AND 51-10-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DENT AT FS 213.5L, L16-17, .023 X 1/2 DX=22, OUT OF LIMIT PER SRM 53-04, FIG 38, SHEET 10. COLD WORKED DENTS, VERIFIED NO CRACKS BY HFEC, FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC9 SRM 51-04, FIG 38 AND 51-10-2.