What was found
FLOOR SUPPORT (60-2576) AT FS 200, T-CAP UPPER SURFACE AND FASTENER HOLES AT FS 160 TO 219 CORRODED. REMOVED, FABRICATED AND INSTALLED NEW FLOOR SUPPORT IAW DC9 SRM 51-10-3, 51-30-2, 51-10-4, 51-10-3 53-01, FIG 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR SUPPORT (60-2576) AT FS 200, T-CAP UPPER SURFACE AND FASTENER HOLES AT FS 160 TO 219 CORRODED. REMOVED, FABRICATED AND INSTALLED NEW FLOOR SUPPORT IAW DC9 SRM 51-10-3, 51-30-2, 51-10-4, 51-10-3 53-01, FIG 1.