What was found
SCHEDULED INSPECTION, THE AFT ENTRY DOOR INTERNAL STRUCTURE UPPER LEFT HAND CORNER HAS A CRACKED BRACKET AT STA 946. REMOVED THE AFT ENTRY DOOR CRACKED BRACKET, DRILLED NEW REPLACEMENT BRACKET, DEBURRED, TREATED, PRIMED AND INSTALLED IAW DC9 SRM 51-10-3, 51-10-4 AND 51-30-5.