Service difficulty report · Door · Gulstm G1159A

Difficulty date
April 8, 2015
Submitted
April 24, 2015
Operation
General aviation
Aircraft
N360MB
Make and model
Gulstm G1159A
Aircraft serial
306
Part
Door
Condition
Malfunctioned
Location
Nlg
Stage of operation
CL
How discovered
9
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ACFT HAD AN AFTER TAKEOFF NOSE GEAR DOOR CLOSING PROBLEM. THE CREW REPORTED A WIND NOISE AND VIBRATION ISSUE AND NOTED THE RED GEAR HANDLE LIGHT WAS ILLUMINATED INDICATING AN INCOMPLETE RETRACTION OF THE LANDING GEAR. THE GEAR WAS EXTENDED AND THE ACFT RETURNED TO BASE FOR INSPECTION. THE ACFT WAS JACKED UP AND A GEAR SWING WAS PERFORMED IN ATTEMPT TO FIND THE SOURCE OF THE PROBLEM IAW NLG INSPECTION CHECK GIII MM 32-02-00, PAGES 601-609. IT WAS DISCOVERED THAT THE GLAND NUT ON THE NOSE GEAR STRUT ASSY WAS NOT FULLY SEATED AND WE DETERMINED THAT THIS CAUSED THE UPLOCK ROLLER TO BE MISALIGNED WITH THE UPLOCK LATCH MECHANISM, THIS MIS-ALIGNMENT THEREFORE CAUSED THE GEAR TO STOP PRIOR TO SIGNALING THE GEAR DOORS TO CLOSE. THE NUT WAS RE-SEATED, MULTIPLE GEAR CYCLES WERE PERFORMED IAW MM 32-00-00 ADJUSTMENT/ TEST, NO DEFECTS WERE NOTED AND THE AIRCRAFT WAS RETURNED TO SERVICE.