Service difficulty report · Valve · Dorner DO328100

Difficulty date
June 25, 2001
Submitted
July 2, 2001
Operation
Air carrier
Aircraft
N431JS
Make and model
Dorner DO328100
Aircraft serial
3028
Aircraft time
15,233 hours, 13,031 cycles
Part
Valve
Part number
4068B000002
Part serial
2052775
Condition
Failed
Location
A/C Bay
Part time
4,129 hours, 3,503 cycles
Stage of operation
TX
How discovered
O
Nature of condition
B
Precautionary procedure
D

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AFTER TAXIING FROM THE GATE, THE FLIGHT ATTENDANT NOTIFIED THE CAPTAIN THAT THERE WAS SMOKE ENTERING THE CABIN. THE CAPTAIN SHUT DOWN THE PACKS AND BLEEDS AND CONFIRMED THERE WAS SMOKE IN THE CABIN. THE CAPTAIN RETURNED TO THE GATE AND DEPLANED THE PASSENGERS. MAINTENANCE INSPECTED AND REPLACED THE PACK VALVE IN ACCORDANCE WITH DORNIER MAINTENANCE MANUAL 21-00-00. OPERATIONAL CHECKS WERE PERFORMED AND THE AIRCRAFT WAS RELEASED FOR SERVICE.