Service difficulty report · Check Valve · Cndair CL6002B19

Difficulty date
May 20, 2007
Submitted
June 8, 2007
Operation
Air carrier
Aircraft
N261PS
Make and model
Cndair CL6002B19
Aircraft serial
7959
Aircraft time
6,758 hours, 6,863 cycles
Engine
Ge CF343B1
Part
Check Valve
Part number
35002300003
Part serial
T0530AB
Condition
Damaged
Location
Rt A/C Pack
Part time
6,812 hours, 6,916 cycles
Stage of operation
TX
How discovered
O
Nature of condition
B, J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

CREW REPORTED RECEIVING A RIGHT HAND PACK OVERHEAT (TEMP) CAUTION MESSAGE WHILE SMELLED SMOKE IN THE CABIN DURING TAXI-IN TO THE GATE. MAINTENANCE INSPECTED AND DEFERRED THE RIGHT HAND PACK PER MEL 21-51-01 -C- OPT 1. MAINTENANCE TROUBLESHOT THE RIGHT HAND PACK SYSTEM. MAINTENANCE REMOVED AND REPLACED THE ACM CHECK VALVE IN ACCORDANCE WITH THE AIRCRAFT MAINTENANCE MANUAL 21-52-07-000/400-801. OPERATIONAL CHECKS WERE PERFORMED. AIRCRAFT WAS RELEASED FOR SERVICE.