Service difficulty report · Valve · Cndair CL6002C10

Difficulty date
August 18, 2012
Submitted
August 23, 2012
Operation
Air carrier
Aircraft
N725PS
Make and model
Cndair CL6002C10
Aircraft serial
10186
Aircraft time
18,828 hours, 18,812 cycles
Part
Valve
Part number
GG43610087
Part serial
0492
Condition
Failed
Location
Ac Bay
Stage of operation
CL
How discovered
O
Nature of condition
O
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

CREW REPORTED THE CABIN TEMPERATURE COULD NOT BE CONTROLLED AFTER TAKEOFF. AIRCRAFT RETURNED TO AIRPORT AND LANDED WITHOUT INCIDENT. MAINTENANCE TROUBLESHOT, REMOVED AND REPLACED THE CROSS BLEED VALVE. THE LEFT HOT AIR SHUT OFF VALVE WAS ALSO REMOVED AND REPLACED. OPERATION CHECKS WERE PERFORMED USING MAINTENANCE MANUALS AND AIRCRAFT WAS RETURNED TO SERVICE.