Service difficulty report · Thermal Switch · Cndair CL6002B19

Difficulty date
January 15, 2015
Submitted
January 20, 2015
Operation
Air carrier
Aircraft
N241PS
Make and model
Cndair CL6002B19
Aircraft serial
7909
Aircraft time
26,384 hours, 26,670 cycles
Part
Thermal Switch
Condition
Failed
Location
Anti-Ice
Stage of operation
CL
How discovered
O
Nature of condition
N
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

CREW REPORTED WING ANTI-ICE DUCT MESSAGE IN FLIGHT WITH LT WING INDICATING RED. OCCURRED AT FL250 CLIMBING TO FL290. CLEARED AFTER FOLLOWING QRH TO CLOSE FOURTEENTH STAGE BLEED VALVES. WINGS HAD BEEN SWITCHED OFF PRIOR TO MESSAGE OCCURRING. CREW DIVERTED TO REMAIN CLEAR OF ICING CONDITIONS AND LANDED WITHOUT INCIDENT. MAINTENANCE TROUBLESHOT, R & R STANDBY OVERHEAT SWITCH AND PERFORMED CHECKS IAW AMM. ACFT RELEASED FOR SERVICE.