Service difficulty report · Warning Message · Cndair CL6002D24

Difficulty date
October 4, 2015
Submitted
October 8, 2015
Operation
Air carrier
Aircraft
N554NN
Make and model
Cndair CL6002D24
Aircraft serial
15334
Aircraft time
2,447 hours, 2,275 cycles
Part
Warning Message
Condition
False Activation
Location
Lt Bleed Valve
Stage of operation
CL
How discovered
O
Nature of condition
N
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

CREW REPORTED LT BLEED VALVE AMBER CAUTION MESSAGE ILLUMINATED ON CLIMBOUT AT 500 FEET. CREW RETURNED TO FIELD AND LANDED WITHOUT INCIDENT. MAINTENANCE PERFORMED OPS CHECKS OF LT ENGINE PRESSURE REGULATING SHUTOFF VALVE AND HIGH PRESSURE VALVE IAW AMM. OPS CHECK GOOD. NO DEFECTS NOTED. ACFT RETURNED TO SERVICE.