What was found
GEAR DISAGREE AFTER RETRACTION, AIR RETURNED TO FIELD, NO ISSUES WITH LANDING AND TAXI. TROUBLESHOT AND FOUND SENSOR PX08 TO BE GREATER THEN .050 OUT OF LIMITS, ADJUSTED THE SENSOR TO BE WITHIN PROPER RANGE, GEAR SWING OPS CHECKED GOOD.