What was found
FLOOR SUPPORT TO FRAME FITTING AT BS 319.7, RBL 42 IS CORRODED. LOCATED, DRILLED AND INSTALLED NEW FLOOR SUPPORT TO FRAME FITTING IAW SRM 51-42-21, AND 51-40-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR SUPPORT TO FRAME FITTING AT BS 319.7, RBL 42 IS CORRODED. LOCATED, DRILLED AND INSTALLED NEW FLOOR SUPPORT TO FRAME FITTING IAW SRM 51-42-21, AND 51-40-11.